40 D-302756
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read [06:ALARM
CANCEL].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [06:ALARM CANCEL].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.7.5 Configuring Power Failure Threshold Period
Here you determine the time interval between AC power failure occurrence and the failure reporting.
Options: 5 minutes (default), 30 minutes, 60 minutes or 180 minutes.
Note: To comply with EN requirements, set to 60 min. max.
To Configure the Power Failure Threshold Period
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read [34:AC FAIL
REP].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [34:AC FAIL REP].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.7.6 Configuring Abort Time
Here you select the length of time allowed by the system to abort an alarm (not applicable to alarms from FIRE, 24H SILENT,
EMERGENCY, GAS, FLOOD and TEMPERATURE zones). The PowerMax10-G2 is programmed to provide an “abort interval”
that starts upon detection of an event. During this interval, the buzzer sounds a warning but the siren remains inactive and the
alarm is not reported. If the user disarms the system within the allowed abort interval, the alarm is aborted.
4:AC FAIL REP
6:ALARM CANCEL
4:
C FAIL REP
1:ENTRY DELAY 1
NTER CODE:
INSTALLER MODE
EADY 00:00
EFINE PANEL
6:
LARM CANCEL
1:ENTRY DELAY 1
EFINE PANEL