TESTING THE SYSTEM
58 D-303223 PowerMaster-10 / PowerMaster-30 User's Guide
Additional Information (Periodic Test)
1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED
will also provide the link quality indication – see PowerMaster-10 / PowerMaster-30 Installer Manual.
4
To skip the SIRENS TEST and select the other devices TEST, press .
5
If the panel's display reads "SIREN P", this indicates that the control panel's siren is currently being
tested.
6
The Periodic test can be performed on a maximum of three sirens including one internal siren. Outdoor
sirens are activated with low volume.
7
If no temperature sensor is enrolled in the system, the display reads
"NO EXISTING DEV.
".
8
The displayed temperature can be in Celsius or Fahrenheit according to the programmed settings of the
Temperature Sensor.
9
How to activate system devices during the "Periodic Test". Make sure the LED on the device lights when
activated, as follows:
Contact sensor:
Open or close the door or window protected by the contact.
Motion sensors: Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors: Perform a "Diagnostic test" as explained in the detector's datasheet.
Keyfob: Activate any of the keyfob buttons.
Keypads: Perform a disarm or arm routine or press any other key that activates the LED.
Repeater: Follow the "Diagnostic Tests" described in the repeater's datasheet.
Other devices: In general, follow the "Diagnostic Tests" described in the device's datasheet or activate
any of its functions.
10
a. Three seconds after the device is displayed, the device LED blinks continuously to assist you to identify
("it's me").
b. To end the session, press the button until the display reads [
<OK> TO EXIT
] then press
.