7.2 Panel Definitions
Panel Definition enables you to customize the control panel and adapt its characteristics
and behavior to the requirements of the particular user.
Standard Support – Select UL, Social Alarm or Disabled.
Operational Mode - Various operational modes used in HHCPC, as follows:
Important: Regardless of the operational mode used, each emergency pendant button and
other wireless device enrolled with an Amber panel should be manually tested regularly
(at least once a week) to determine if there is a low battery condition, identify radio
interference and to protect against faults.
Mode Usage and Functionality
Single User
(1)
Suitable for general use inside a home or within congregate living
facilities. Up to 29 detectors may be used in this mode, out of which up
to 2 emergency pendant-buttons and/or fall detectors may be enrolled
for signaling alarm (emergency) and/or any other trouble condition (for
example, low battery in pendant). Single User Mode is supported in:
AMBER SELECT, AMBER SELECTX, AMBER CLASSIC,
AMBER CLASSICX, AMBER BASIC, AMBER LINK and AMBER
GSLA.
Multi User
(1)
Suitable for use within congregate living facilities. Up to 29 emergency
pendant buttons and/or fall detectors may be enrolled for signaling
alarm (emergency) and/or any other trouble condition (for example,
low battery in pendant). Multi User Mode is supported in: AMBER
SELECT, AMBER SELECTX, AMBER CLASSIC, and AMBER
CLASSICX.
Note: This mode does NOT support Device Test Check or individual
reminders.
Fire Only
(1)
Designed to trigger fire alerts only. The control panel functions as a
fire alarm system, and up to 29 detectors (non-pendant) may be
enrolled. Fire Only Mode is supported in: AMBER SELECT,
AMBER SELECTX, AMBER CLASSIC and AMBER CLASSICX.
Note: This mode does NOT support Device Test Check, custom audio
files, individual reminders or the enrollment or monitoring of
pendants.